                 FLUID EXTRACTOR

                 Manual & Pneumatic 2 in 1


                                                                                                                                                                                                          Select and inset the appropriate diameter
                                                                                  Quick, easy                                                                                                             extracting tube into the dipstick hole until
                                                                                                                                                                                                          it reaches the bottom of the oil pan.
                                                                                    and clean                                                                                                             Connect the main tube to the unit and to
                                                                                                                                                                  1                                  2    the extracting tube.

                                                                                                                                        Remove the oil dipstic


                                                                                           Automatically
                                                                                           stop function
                                                                                                                                    by                                                              by

                                                                                                                                                              Ensure that the “open & close valve
                                                                                                                                                              lever” is in the “ close ” position.
                                                                           ILLUSTRATIONS                                                                      Connect the air compressor
                                                                                                                                                              air line hose with the quick coupler.
                                                                           Oil Inlet / Outlet &         Pump Handle
                                                                           Main Tube Connection


                                                                                                        Carry Handle
                                                                                                                                      3
                                                                                                        Release Valve                                                                                                         3
                                                                                                        Button
                                                                                                        Open & Close
                                                                                                        Valve Lever
                                                                                                                                                             Then switch the lever to the “ open ”
                                                                                                                                                             position.
                                                                                                                                                             The unit will then automatically start
                                                                                                                                                              to extract the oil.
                                                                                       Equipped with parts
                                                                                    ① connector


                                                                                    ② tube joint (red)

                                                                                                                                      4                                                                                        4
                     10.5L Type                    6L Type                          ③ tube joint (black)




                     Suitable for
                    Any Vehicles

                                                                                                                                                                Prior to using the extractor again ensure
                                                                                                                                                                to press the  “Release  Valve” for at least
                                                                                                                                                                5 seconds to release any vacuum that
                                                                                                                                                                 may have formed in the inner pump tube.


                   Automobile                         ATV             Boat                       Machine tool